You have no items in your shopping cart.

Subtotal: 0.00

Lab Experiment for Synchro Transmitter and Receiver

EXPERIMENTAL SECTION

 

EXPERIMENT-1

 

AIM

To measure the Stator output voltage with respect to rotor position and plot the graph.

EQUIPMENT REQUIRED

 

PROCEDURE

  • Connect Digital Voltmeter across the any two Stator output of Synchro transmitter.
  • Connect Synchro transmitter stator outputs to corresponding Stator terminals of Synchro receiver.
  • Power ‘ON’ the all ON/OFF Switches
  • Verify the Stator output voltage of 0V at 0 degree, if it is not make 0V at 0 degree toadjust the pointer of both transmitter and Receiver.
  • Adjust the transmitter rotor position Step by Step.
  • Now note down the output voltage for various rotor position in the table 1.
  • Repeat the Same procedure for other pair of Synchro transmitter coils.

 

Table-1



SL. NO

Synchro transmitter

Rotor Position (degree)

Stator Output (V)

     
 



MOTOR GRAPH





The following table is used to Synchro transmitter Stator Output Voltage for variousRotor position.

 

SL . No

Rotor Position (degree)

Stator Output (V)

1

2

3

4

5

 

0° and 180°

0° to 90°

90° to 180°

180° to 270°

270° to 360°

 

0V

0V to 40V

40V to 0V

0V to 40V

40V to 0V

 

 



RESULT

Thus the Synchro transmitter Stator output voltage with respect to rotor position was studied and the graph was plotted.

EXPERIMENT-2



AIM

To study the Rotor position of Synchro transmitter and Receiver

EQUIPMENT REQUIRED

 

PROCEDURE

  • Connect Digital Voltmeter across to the any two Stator output of Synchro transmitter.
  • Connect Synchro transmitter stator outputs to corresponding Stator terminals of Synchro receiver.
  • Power ‘ON’ the all ON/OFF Switches
  • Verify the Stator output voltage 0V at 0 degree, if it is not make 0V at 0 degree toadjust the pointer of both transmitter and Receiver.
  • Adjust the transmitter rotor position step by step by using knob
  • Now note down the rotor position of transmitter and receiver in the table-2.

 

Table-2



SL.No

Synchro transmitter Rotor Position (degree)

 

Synchro Receiver Rotor

Position (degree)

 

Error = Rotor position

(Transmitter - Receive

       
 

 

RESULT

Thus the Rotor Position of Synchro. transmitter and Receiver was Studied.