In TRICAC Phase Control, the firing angle, or point during the half-cycle at which
the SCR is triggered, determines the amount of current which flows through the device.
It acts as a high-speed switch which is open for the first part of the cycle, and
then closes to allow power flow after the trigger pulse is applied.